Turb4000
Seriel
Ref:
TurbIntE
___IEEE1451.2 STIM
Compatible, 1451.1 NCAP Network support. Analog and Digital Signals
Output. Remote Setup and Operate.
n
Continuous
analysis. Direct measurement in sample
n
Accurate and
reliable, low-maintenance
n
Self diagnostic,
professional intelligent, Menu-driven digital user interface
n
Auto diagnostic
and alarm, optional purge or flush and bubble sucker accessories
n
Easy maintenance
__ on time clear or replace of sensor in sito
n
Data log of
measurements for day/month/year
n
One-year
warranty
n
Industrial
Process Water
n
Boiler/Cooling Water Flow Application
n
Ultrapure Water
Application
n
Wastewater Treatment Application
n
Drinking Water Treatment
n
Boiler/Cooling Generation Flow Application
n
Agriculture and Aquaculture Water
n
Auto temperature
compensation
n
User calibration at field to get high accuracy application
n
One sample or on-line sample correction function available
n
Experiences low power design, maybe drived by battery or solar
battery in remote area.
Linear analog signal output, 0/4 to 20 mA select. dedault
status is 0 to 20 mA
RS232 serial port always available, RS485 attached as to
BD5xB upper configuration.
Power supply: DC 9 to 24 V; comsumption<100mAx5V
Intrinsic safe design
Alarm drive output available
ADC resolution: 16bit
For more details, please refer to : BD4&5IntE
Specifications Table for Different
Design
Model |
Specifications |
Turb.1t 4110 Turbidimeter Transparent photometer |
For
Pure and ultra pure water. Range:0-200
NTU Resolution:
0.01NTU Accuracy:
0-20 ±2%R
; 20-2,00 ±5%R Repeatability:
1%FS Temperature:
0-60℃ Pressure:<10 kgf/cm2. Insert
Deepth: 120mm Connect:
NPT1”, or ZG1” |
Turb.2t 4120 Turbidimeter Double Wave Length Photometer Only
for complex background Applicatoin |
Range:
0-2;0-20;0-200;0-2000 NTU ; Accuracy:
±2%FS/
low; ±5%FS/High
Repeatability:
<±1%
FS Resolution:
0.05%FS Linearity:
<±1%
FS Response:
10s-2mins Flow:100-1000ml/min Temperature:
0-60℃ Pressure:<10
kgf/cm2. Dip
Size: D177*312mm CLA
Size: |
Turb.2r 4230 Turbidimeter 3Sensor Disperse (MLSS, high suspended or floating materials
application) |
Range:
MLSS: 0-50,5000mg/L Accuracy:±2-5%
FS Repeatability:±1%
FS; Resolution:
0.1%FS; Flow:100-1000ml/min Temperature:
0-60℃ Pressure:<10kgf/cm2. Insert
Deepth: 120mm Connect:
NPT1”, or ZG1” |
Turb.90d 4210_640 Turbidimeter 90° dispersive Turb.90d 4210_640 for USEPA
180.1 Turb.90d 4210_880 for ISO 7027 / EN 27027 |
Pure,
drinking water, and any common fields. Range:
0-100 NPT, Max 100g/L Accuracy:
±2-5%
FS Repeatability:
<±1%R Resolution:
0.01NTU Temperature:
0-50℃ Pressure:<10 kgf/cm2. Insert
Deepth: 120mm Connect:
NPT1”, or ZG1” |
Turb.90d 4210_640 Turbidimeter
____The most popular turbidity technology
|
Feature |
Application |
Turb4210D |
Benefits at a glance •Measuring range from 0.01 FNU to 100 g/l – from completely clear to completely black •Scratch-proof sapphire windows •Compact shock-proof design •Integrated temperature measurement •Inclined flat sensor surface uses medium flow to increase
self-cleaning effect and repels water bubbles •Sapphire measuring window •Flow assembly option available for gas bubble removal •Measurement under pressure to
avoid degassing •For direct installation in water
pipes, •For
installations in pipes or basins •Simple commissioning •3-point calibration and 1-point adjustment •7 calibration data records
according to customer specifications can be
stored •Wiper cleaning integrated or
retrofitted •Flat sensor surface uses medium
flow to increase self-cleaning effect |
Areas of application Optical solids content
measurement is indispensable as a
regulating variable for operation in
following areas: Sewage treatment plants – Primary sludge – Activated sludge – Returned sludge – Putrefied sludge – Outlet Paper – Monitoring of sieve
water – Water processing Concrete – Measurement of soiling Production Water processing Water monitoring |
Turb4210DU |
Range:
0.01-2000 FNUL Using
one cap to avoid any interface from wall and other light sources Special
for open vessel, lake, other otherwise exposed to sunshine |
The
same |
Turb4210DTU |
Range:
0.001- FNUL Special
for low limit detect |
Pure
water Boiler
water |
SPM4210MLSS |
0-100g/L
|
MLSS |
Problem |
Solution |
Bubble |
Use BulbleSuck,
or Ultra sonic bubble driver |
Color |
The best
way is to use Turb.2t 4120 Turbidimeter Or choose
860nm or 680nm to reduce the influence |
Temperature |
Self
corrected in our products |
Installation and Sampling Accessory
CPA1 |
G 1” or 1”NPT insertion installation |
|
CPA2 |
Dip
accessory, extend CS1 with 1” pipe |
|
CPA3 |
Sinking
accessory, CS1with extending pipe, frame, and clearing system |
|
CPA4 |
By flow
installation, CS1with one 1” cross |
|
BubbleSuck |
Flow throw
type, fitting to CS1 insertion directly |
1/4” inlet
and outlet |
..\..\Water\Transducer\WaterSTIM&MeterDimension_E.doc
BIG DIPPER TECHNOCHEM INSTITUTECall: (86) 10-6257.3897; 8264.9388 Fax: (86) 10-6252.3517;
P.o.Box:
603 BDTI Beijing, China 100190 http://www.BD-research.com/ Email: support@big-dipper.us; sales@big-dipper.us;
Copyright
reserved.
..\Water\Transducer\WaterSTIM&MeterDimension_E.htm
More Information for Water Transducers
Water transducer: http://www.BD-research.com/Products/Water/
Electrochemical
transducer:http://www.BD-research.com/Products/BD3000/CPT3200/CPT3200IntE.htm
Electrochemical
sensor:
http://www.BD-research.com/Products/BD3000/CPelectrodeList_E.htm
Conductivity transducer:http://www.BD-research.com/Products/Liquid/Water/SCT/SCTIntE.htm
Turbidity
transducer:http://www.BD-research.com/Products/Liquid/Water/Turbidity/TurbIntE.htm
Mud concentration transducer: http://www.BD-research.com/Products/Liquid/Water/Mud/MudIntE.htm
TDO(TOC/COD/BOD) transducer: http://www.BD-research.com/Products/Liquid/Water/TDO/UV4120TDOIntE.htm
Multi-parameters transducer: http://www.BD-research.com/Products/Liquid/Water/wm10/wm10IntE.htm
Water transducer application: <examples>
http://www.BD-research.com/Meters/
BD4&5Introduction: http://www.BD-research.com/Meters/BD4_IntE.htm
BD4&5 Functions: http://www.BD-research.com/Meters/BD4_TB_E.thm
BD4&5 Selection: http://www.BD-research.com/Meters/BD4_Sel_E.htm
BD4_5Configuration: http://www.BD-research.com/MetersBD4_Cfg_E.htm
BD4Application: http://www.BD-research.com/Meters/BD4_AG_E.htm
Related
Technical References:
http://www.BD-research.com/Network/
Scom Protocol
STIMcom Protocol
IEEE1451.1 NCAP Protocol
IEEE1451.2 STIM Protocol
Water DO3230 Dissolved
Oxygen Transducer,TMP36 Temperature Transducer,SCT1121 Conductivity Transducer,
SCT1122 Conductivity Transducer, Salinity Transducer, SCT1130 Conductivity
Transducer, Mud1204 Concentration Transducer, Turb4210D Turbidity Transducer,
Turb4210DU Turbidity Transducer, Turb4210DTU Turbidity Transducer, MLSS4210D
Turbidity Transducer, pH Transducer, ORP Transducer, ISE Transducer, Dissolved
Gas Transducer;