Hand held BD5w series Multi-sensors

Portable Water Analyzer 

for lab and field smart test of

pH, conductivity /salinity, DO, Turbidity and other electro-chemical parameters

Ref: HBD5WMSIntE

Date:2002-05-23

 

l         Easy-to-use and Smart Test

l         high and low alarm limits and display hold

l         2x16 LCD Display,5x4 Keypad

l         Known Addition, TKA Methods

l         8 Standards Calibration for Turbidity and SCT

l         Automatic Blank Correction

l         Datalog, Readout and Print out support

l         Communication to PC Acquisition System, by STIMcom/Modbus in accordance with IEEE 1451.2 STIM protocol

Advanced instrumental features include calibration edit, and temperature -compensated ISE measurement. Use calibration edit to review, delete or re-measure calibration standards.

 

HBD5WMS Handheld instruments has capability to test up to 45 water quality parameters with single probe replaceable, and offering temperature compensation as well.

 

Ease of operation, data display and retrieval, and advanced analytical techniques for performing sophisticated analyses make the HBD4/5w the best choice for the multi-user lab and research chemist, as well to field patrol.

HBD5W

Versatile Single Channel, Multi Parameter System

n          Rugged, reliable, versatile

n          Field-replaceable ISE, Galvanic, conductivity and turbidity

n          User setup unit, mV, pH, mg/L etc.

n          RS-232 and Compatible with IEEE 1451.2 STIM data analysis software

n          Easy-to-use, screw-on sensor replacement

n          IAP user-upgradeable software via internet or peer to peer support

n          5 year warranty on the instrument; 1-year on the probe module and cables

n          Available with 1.3m cable default (user order specification acceptable)

n          Stores over 3,000 frame datalog, time and date stamped

 

 

Replace independently of ISE/pH/mV/ORP/Temperature /Conductivity and Turbidity Sensors:

 including Ag+/S-2,BF4-,Br-,Ca+2,Ca+2/Mg+2,Cd+2, CO2/CO3-2, Cl-/Cl2, ClO4-,CN-,Cu+2,F-,K+,I-,Li+,Na+, (NH3/NH4+), NO3-, (NOx)i/NO2-, ORP,Pb+2,pH,SCN-, and turbidity, Conductivity, Dissolved oxygen

Support H-series conductivity and turbidity sensors, and any other ISE sensors. Even from other manufacturers worldwide, just need to connect according the instructions

 

 

Specifications:

 

 

 

Analog Test Resolution:

16-24 bits, equal to better than ppm to 100%

 

 

Auto range: -1.25 to +1.25V scale

No any operation to switch range

 

 

Environ Temperature

-10 to 50 °C

 

 

Environ Humidity

10 to 90%RH

 

 

Supply

Lithium Rechargeable Cell or DC6-24V Source

 

 

Size(Analyzer only)

98W×180H×35D (mm)

 

Weight (net)

0.5 kg

Sensors Specifications

Parameters

Descriptions

DO3230 Dissolved Oxygen Sensor

Galvanic Cell

Range:

0 to 500% air saturation; 0 to 50 mg/L

Accuracy:

0 to 200% air saturation, ± 2% of the reading or 2% air saturation; whichever is greater

Resolution:

0.1% air saturation; 0.01 mg/L

Sensor Size:

f20x110 mm

TMP36 Temperature Sensor

Thermistor IC

Range:

-40 to 120°C

Accuracy:

± 0.1°C

Resolution:

0.1°C

Sensor Size:

f10x110 mm

SCT1121 Conductivity Sensor

Pulse-electrode cell

K=0.1,1.0/cm

Range:

0 to 500ms/cm

Accuracy:

± 1.5% of reading

Resolution:

0.04 uS/cm

Methods:

USEPA 120.1

Standard Method 2510-B for wastewater

Sensor Size:

f11x110 mm

SCT1122 Conductivity Sensor

2-electrode cell with auto-ranging

Range:

0 to 100, up to 1000 mS/cm

Accuracy:

± 0.5% of reading, or 0.1% of step whichever is greater

Resolution:

0.04 uS/cm to 0.1 mS/cm (range-dependent)

Salinity Sensor Type;

Calculated from conductivity and temperature

Range:

0 to 70 ppt

Accuracy:

± 1.0% of reading or 0.1 ppt, whichever is greater

Resolution:

0.01 ppt

Methods:

USEPA 120.1

Standard Method 2510-B for wastewater

Sensor Size:

f50x300 mm

SCT1130 Conductivity Sensor

2-electrode high frequency attenuation

Range:

0 to 30% TDS

Accuracy:

± 0.1% FS

Resolution:

0.1%

Sensor Size:

f24x300 mm

Mud1204 Concentration Sensor

high frequency attenuation

Range:

0 to 60% TDS

Accuracy:

± 0.1% FS

Resolution:

0.1%

Sensor Size:

f24x300 mm

Turb4210D Turbidity Sensor

90° dispersion

Range:

0-2000 NTU

Accuracy:

± 0.5% of reading, ± 0.1% FS whichever is greater

Resolution:

1 NTU

Methods:

Turb.90d 4210_640 meets USEPA 180.1

Turb.90d 4210_880 meets ISO 7027 / EN 27027

Sensor Size:

f50x300 mm

Turb4210DU Turbidity Sensor

90° dispersion

Range:

0-2000 NTU

Accuracy:

± 0.5% of reading, ± 0.1% FS whichever is greater

Resolution:

0.01 NTU

Methods:

Turb.90d 4210_640 meets USEPA 180.1

Turb.90d 4210_880 meets ISO 7027 / EN 27027

Sensor Size:

f50x300 mm

Turb4210DTU Turbidity Sensor

90° dispersion

Range:

0-200 NTU

Accuracy:

± 0.5% of reading, ± 0.1% FS whichever is greater

Resolution:

0.001 NTU

Methods:

Turb.90d 4210_640 meets USEPA 180.1

Turb.90d 4210_880 meets ISO 7027 / EN 27027

Sensor Size:

f50x300 mm

MLSS4210D Turbidity Sensor

90° dispersion

Range:

0-10,Max to 100g/L

Accuracy:

± 0.5% of reading, ± 0.1% FS whichever is greater

Resolution:

0.1mg/L(HBD5)

0.05%FS(HBD4)

Methods:

Adapted from <Sewage and Industrial Wastes,31,1159(1959)

Sensor Size:

f50x300 mm

pH Sensor Type:

Glass combination electrode

Range:

0 to 14 pH

Accuracy:

±0.2 pH

Resolution:

0.01 pH

Sensor Size:

f10x110 mm

ORP Sensor Type:

Platinum button

Range:

-999 to +999 mV

Accuracy:

± 10 mV

Resolution:

0.1 mV

Sensor Size:

f10x110 mm

ISE Sensor Type:

Electrochem

Range:

Refer to sensor details