MS1204-series  

Liquid Moisture Transmitter

Moisture Technology  Application in lquids & Oil Industry

RefliqMS1204IntE  2001v1

n         MS1204 Mircrowave Atenuation mothed

n         Auto Temperature Compensation

n         Less Influeency of Salinity

n         0.01-100% real time measurement

n         Rugged, No maintenance running

n         MS1204 Keep best specificaton all over 0.01%-100% application for oil

n         Specially used to oil field, petroleum.refinery plant, and other chemical process

n         IEEE1451.2 STIM Transducer, 0/4-20mA outputs and RS232/RS485 seriel communication port.

n         IEEE1451.1 NCAP analyzer/controller, new design for new century network instruments.

 

MS1204 series Moisture SensorMS1204 is one experienced design of high frequicy complex technology, so it just overcomes the shortcomings of being too dumb as that of microwave and too sensitive as that of capacity technology. Combined with modern instrumental technology,such as temperature compensation etc. MS1204 keep 0.01 stable resolution to moisture in oil, but less sensitive to dissolved salts, for it is very important in application in oil field, and best accuracy among 70-100% moisture content is expected.

Principle for MS1204 Moisture Detect

Because of the high polarity of water molecules, water behaves more sensitive than any other materials in high frequency electronic magnetic field. MS1204 series is simply designed based on this verified physical property. In the chamber of the sensor applied stable HF power, the water and other materials all exhaust the energy of the EMW, but water takes about 70 times of that by oil alike materials under the same condition. This is the point we can detect moisture selectively from the sample body.

Of course the principle is too easy, not equal the sensor it easy to make. As our lab has being working on this technology for 40 years more, so experienced than most comrades.

BD5 Smart TransducerDesigned with the most new MCU from USA, it’s basic scientific algorithm is based on our 40 years research works, and the shell softare is designed complete according to IEEE 1451.2 STIM standard, it was original from the STIM of Honeywell.

BD4 NCAP ControllerThis controller is designed according IEEE1451.1 standard. Although is not concerned to the main moisture techonology, but very powerful in high level net work application. For it is based on data communication, so not only high accuracy message can be transferred to remote office, but also can setup the transducer completely at remote control center. 

Application

l         Most organic liquids

l         All kinds of oil, including crude oil, fuel oil, mechanic lubricants and insulator electronic oil, and food oil

l         Adhesives, Coatings , Emulsions, Inks and Dyes, Paints, Polymers, Resins,Asphalt, Glass

l         Chemicals, Solvents, Pharmaceuticals

l         Confectionery, Fermentation Products, Syrup

l         Mineral Processing

l         Oils, Oil and Gas Production, Petroleum Products , Fuel, Lubricants

l         Paper Industry,Power Industry

Application System Configuration

Field Units

Quatity

Remote Singnal

Human Interface

Insertion Type Transducer

Byflow  Type Transducer

1

0/4 to 20 mA

 

Other standard displayer

Same

32/128/255

RS485 /IEEE1451.2

p-BD4xCD Controller

Same

32/128/255

RS485/Modbus

p-BD4xND Network Controller

Same

Popular

RS232/RS485

H-Calibrator_1451.2

MS1204 series Moisture Transducer Selection:

Application Guiding:

Materials Characteristics

Application

Suitable Technology

1ppm-2% moisture of oil

analysis

MS4120 : NIR photometer

0.01-10% moisture of oil

analysis

MSL1204bf: high frequicy electronic attenuation

0.1-100% moisture of oil

analysis

MS1204p: high frequicy electronic attenuation

Oil leakage,level switch

detect

MS1130 :high frequicy conductivity

High desolved saults

analysis

MS4120 : NIR photometer

High Electric Constancy Liquids,>40

analysis

MS4120 : NIR photometer

Oil/water interface

monitoring

MS1204DP : high frequicy electronic attenuation

Level and Interface measurement

monitoring

LM1410: Phase difference technology

 

 

Selection Guiding by Range

Range

Transducer

H_Operator

BD4xCD

 Controller

Lmixer

On-line Mixer

BD4CND

Network Controller

DSP2000

Remote Operator

ISN2000

Instrument Station

0-1350ppm

TBD5xC_MSL4120

 

0.01-10%

TBD5xC_MSL1204bf

 

 

 

 

 

0.01-10%

TBD5xC_MSL1204bf

 

 

 

 

 

0.01-10%

TBD5xC_MSL1204bf

 

 

 

 

 

0.01-10%

TBD5xC_MSL1204bf

 

 

 

 

 

0-60%

TBD5xC_MS1204p

 

 

 

 

 

0-60%

TBD5xC_MS1204p

 

 

 

 

 

0-60%

TBD5xC_MS1204p

 

 

 

 

 

0-60%

TBD5xC_MS1204p

 

 

 

 

 

0-100%

TBD5xC_MS1204p

 

 

 

 

0-100%

TBD5xC_MS1204p

 

 

 

 

0-100%

TBD5xC_MS1204p

 

 

 

 

0-100%

TBD5xC_MS1204p

 

 

 

 

 

 

 

Key board,LCD Display

0/4 to 20 mA Output

RS232/RS485

IEEE1451.2 Smart Sensor

Wireless Net, Modem Accessaries.

Refer to <BD4/5 Family Controller>

On-line Mixing of liquids mixture

Modbus Network, FFbus, ControlNet, Lonworks, Profibus, CAN  field bus might surport by order.

Other function is the same as BD4xCD

Deluxe Displayer

Other function is the same as BD4CND

BigFoot WebServe included

Other function is the same as DSP2000

u       Details should refer to special materials


MS-series Liquid Moisture Technology Application

Moisture Measurement Technologic Instruments

Selection Guiding

 

RefLiqMSSel_Table_E

Version: 2001v1

MS1204 Transducer Model Selection

 

Type

Insert

Insert

Insert

Flow throw

By flow

Model

MS1204pp

MS1204pc

MSL1204pp

NS1204H

MSL1204B

Connect

ZG1”, 1”NPT

Flange by order

ZG1”, 1”NPT

Flange by order

F185

F150

ZG3/4”3/4”NPT

Direction

Facing flow

Facing flow

Facing flow

Inlet, down

Outlet, upper

Inlet, down

Outlet, upper

Position

Perpendicular *

Perpendicular

Perpendicular

Perpendicular

Perpendicular

Size of insert

440xf24

440 xf24

500 xf60

 

 

T.Length(mm)

800

800

850

1070/H.D.600

760/H.D400

Dia. Of in/out(mm)

 

 

 

Dg50/ Dg50

3/4”, 3/4”

Weight(kg)

4

4

7

30

25

Sample temperature

100 ~350°C

100~350°C

100~350°C

100~350°C

100°C

Sample pressure

1.6~4.0MPa

1.6~4.0MPa

1.6~4.0MPa

1.6~4.0MPa

1.6~4.0MPa

Range

0.1~100%

0.1-100%

0.02-10%

0.1-100%

0.01-10%

Resolution

0.05%

0.05%

0.02%

0.1%

0.01%

Repeatability

+/-0.1%

or 0.1%FS

+/-0.1%

or 0.1%FS

+/-0.05%

or 0.1%FS

+/-0.5~1%

or 0.1%FS

+/-0.02%

or 0.1%FS

Advantage

Versatile

Simple set

Well EMC

Versatile,for viscous

Small flow  resis.

High resolution

Well EMC

High moisture

Average sampling

Stable low moisture for crisis conditions

 

 

 

 

 

 

Application

Anywhere

Anywhere

Oil Union out

Process

Well field

Union input

Oil gauge

Process

l        Position is described relative to earth. Horizontal is ok too if there is less bubbles inside of flow

 

 

Return to Moisture homepage

 

BIG DIPPER TECHNOCHEM INSTITUTE
Call:(86)10-8264.0226; 8264.0225;
Fax: (86)10-8264.0221;
P.o.Box: 603 BDTI
Beijing, China 100190
http://www.BD-research.com/
Email: support@big-dipper.us    sales@big-dipper.us
http://www.BD-research.com/Products/Moisture/index.htm

CopyRight Reserved


 

.

For quick selection to moisture measuring system, refer to <Selection Guiding>,

URLhttp://www.BD-research.com/Products/Moisture/liqMoisture/LiqMS_SG_E.htm

Further Information about BD4/5xC electronics, please refer to:

URL: http://www.BD-research.com/Products/Meters/

For system design and configuration, Refer to:

URL : http://www.BD-research.com/Products/Moisture/liqMoisture/liqMS_Cfg_E.htm

For more details for selection, Refer to

URL: http://www.BD-research.com/Products/Moisture/liqMoisture/LiqMS_Sel_E.htm

To lean information of moisture detecting technology, refer to:

URL : http://www.BD-research.com/Products/Moisture/liqMoisture/liqMS_TB_E.htm

If you need help from our specialist, please down load the <User application data from>

               URL: http://www.BD-research.com/Products/Moisture/liqMoisture/lMS_AS_E.htm  [.doc]