SmartTest Series

Hand held liq-MS2100 Moisture Meter

 

Trace Moisture Analyzer

Ref: H-lMS2123

Version: 2002-02-26

Ideal for low budget laboratories and smart field test for pure liquid application

n        Trace moisture smart test

n        Temperature compensation

n        Scientific algorithm for high accuracy

n        Accurate and reliable, rugged design

n        Quickly response, <15 sec at typical cases

n        Self diagnostic, professional intelligent, Menu-driven digital user interface

n        Auto diagnostic and alarm

n        Data log of measurements, read and print out, or download to PC supported

Advantage

Economic and sensitive.

Shortcomings

Need start from zero state, and 10 mins to be stable for each test.

Features

l         Not necessary to calibrate

l         High accuracy

l         Fast response

l         Stable, low drift performance

l         Chemically resistant

Applications

l         Transformer Oil

l         Machine oil or lubricants

l         Other organic liquid chemicals

l         Moisture leak detection

Note: For more chemicals application rather than oils, please contact our engineer for verification.

 

Technical specifications

l          Measurement range:

Moisture: 0-120 ppm  Oil @ 20°C

l          Accuracy:  ±2% of reading, 0-1.00 aw, 25 °C;

l          Operating temperature:-40 to 85/140 °C

l          Working Pressure: N:<0.3 Mpa; p:<1.0 Mpa

l          Sensor Interchangeability: ±5% of reading

l          Hysteresis ±1.2% of reading

l          Repeatability ±0.5% of reading

l          Response Time: 15 sec typical at 25 °C

l          Stability: ±1% of reading /typical at 0.50 aw in 5 years

l          MS2123-01 Possibly detect liquids:Ammonia Hydroxide, Acetone, Ethanol, Methanol, Formaldehyde ,Benzene, Toluene, Xylene

 

Compatibility to Standard

Consistent with ASTM D-4928 after calibration in oil moisture test

Test Method.

Prepare the sample in one 100 to 200mL

 

Measuring Method

Configuration

Introduction

Usage

ERH/ Non-contact

Insert the sensor into limited depth, so that the edge of the cup was immerged, but sensor is in top space air. This is condition for Non-contact test, suitable for rigorous solvents;

Liquid

Direct/ Insertion

Directly insert the sensor into liquid. Then read the data in chosen time. Usually 20seconds

Liquid

 

Application Suits

Model

Technical information

HBD5lMS2123-010-N14

Repeatability: <±0.5% FS;

Sample temperature: -40 to 85°C

HBD5lMS2123-022-N14

Repeatability: <±1.5% FS;

Sample temperature: -40 to 140°C

 

Configuration for Moisture Analyzers

Basic Parts List for the Analyzer Suit

  Items

Model

Available Type

Remarks

Analyzer

H-BD5

 

included

Moisture Probe

H-MS2123N14

selection

included

Battery

 

 

included

Charger

 

 

Specify the user local power standard, 110 V or 220V AC

Packing Case

 

 

Included

 

 

 

 

Standard Optional Probe

HMS2123N probe

Specifications

 

MS2123-01-M12T85

Repeatability: <±0.5% FS;

Sample temperature: -40 to 85°C

Size: Dia.: Ø14; Length:120mm

Weight: 150g

 

MS2123-022-M12T140

Repeatability: <±1.5% FS;

Sample temperature: -40 to 140°C

Size: Dia.: Ø14; Length:240mm

Weight: 300g

 

 

BIG DIPPER TECHNOCHEM INSTITUTE
Call:(86)10-8264.0226; 8264.0225;
Fax: (86)10-8264.0221;
P.o.Box: 603 BDTI
Beijing, China 100190
Email: support@big-dipper.us    sales@big-dipper.us