Gas Analysis for Air and Contaminants Emission

Portable Instrument

p-Smoke2000 Portable Contaminants Emissions Gas Analyzer      [Introduction]
p-Flue2000 Flue Gas Analyzer        [Introduction]
p-Auto2000 Automotive Exhaust Analyzer       [Introduction]
  • Infra-red bench & sensors inside.
  • Fast 30-second warms up
  • Ultra-compact - 32mm x 42mm x 150mm
  • Combined technology: infra-red & electrochemical
  • 5 gases embedded and one or two gas sensor might added by user¡¯s order
  • 1 watt power requirement, Battery supply. 
  • ASM/BAR 97, OIML Class 0 applied for Flue and automotive exhaust analysis
p-Air2000 Portable Air Contaminants Analyzer     [Introduction]

p-Air2000R Portable Indoor Air Contaminants Analyzer     [Introduction]

  • T:-30-100¡æ;
  • HR:20-95%RH; 
  • SO2:0-1,10,100ppmv; 
  • H2S:0-1,10,100ppmv; 
  • CO:0-500ppm; 
  • NO2:0-10ppm;
  • NO:0-10,1000ppm; 
  • NH3:0-50ppm; 
  • VOCs:0-1000ppm; 
  • O3:0-2,5,10,20ppm; 
  • Noise:35-130dB; 
  • SPM:0.01-100mg/M3
p-Gas2000 Air Gas Analyzer          [Introduction]  [User's application dataform]

Parameters defined by user's order. For application with air backgrounds.

p-Gas4820 Gas Analyzer          [Introduction]  [User's application dataform]

For critic requirements of industry applications
Professional
Specifications
Application
Organic Vapor Analyzer
0.1ppm -100% LEL
LDL<1ppm for mostt gases£»
2 specified gases calibration in plant;
Chemical process;
Gas leakage detector;
Environ monitoring
Waste Anesthetic Gases and Vapors Analyzer
10ppm-1% Vol;
4 specified gases calibration in plant; Nitrous Oxide, Enflurance, Halothane, Methoxyflurane, Fluoroxene
Hospital Environ;
Anesthetic Agent Detection;
Engineering Servic;
industrial hygiene monitoring;
Surgical, Nursing, Dental, and Research Services;
Flue gas analyzer
Defined by industry
10ppm-100% Vol;
LDL<10ppm for mostt gases
2 specified gases calibration in plant;
Industry Smoke Analysis
Flue Emissions analyzer
Defined by industry
10ppm-100% Vol;
LDL<10ppm for mostt gases
8 specified gases calibration in plant;
Flue Gas contaminants Analysis
Ambient Air Quality Analyzer
36 more environ air pollution gas detect supported,
Most gas LDL::0.1ppm;
7 specified gases calibration in plant;
Environ monitoring, and urban air pollution surveys;
ISO 14000 / ISO 14001 Monitor
Malodorous Compounds Analyzer
36 more gas detect supported,
Most gas LDL::0.1ppm
7 specified gases calibration in plant;
Environ monitoring, and urban air pollution surveys;
ISO 14000 / ISO 14001 Monitor
Indoor Air Quality Analyzer
36 more gas detect supported,
Most gas LDL::0.1ppm
12 specified gases calibration in plant;
Environ monitoring, and urban air pollution surveys;
ISO 14000 / ISO 14001 Monitor
Emergency Response Gas Analyzer
50s gas detect possible;
10 specified gases calibration in plant;
Most gas LDL::0.1ppm
Public safety department;
General toxic gases;
Chemical weapon agents included;
Atmosphere Analyzer
188 more gas detect supported,
Most gas LDL::10ppb;
16 specified gases calibration in plant;
Hazardous air pollutants analysis ;
Atmosphere Analysis;
Environmental management evaluation;

¡¡

¡¡

Air2000 Station:           [Introduction]

Fixed in-situ, or car installation. Enhanced data communication equipment, such as modem connection, radio communication, instrument network, intranet, Internet mange. Solar power supply attachments.

Contaminants Emission Monitoring System (CEMS) & Flue Gas Analyzer          [Introduction

User configuration.

¡¡

BIG DIPPER TECHNOCHEM INSTITUTE
Call£º010-8264.0226;
Fax: 010-8264.0221;
P.o.Box: 603 BDTI
Beijing, China 100080
http://www.fullsense.com/
email: sales@fullsense.com        sales@bigdipper-technochem.com
email: engineer@fullsense.com

¡¡

/**/